Why This Combination Is Good News
Your heat interface unit does two separate jobs inside one box. Hot water from the building's communal system — the primary circuit — arrives at your flat. The HIU then uses that heat twice over: once through a plate heat exchanger to make your domestic hot water on demand, and once to feed your radiator circuit.
So if your hot water is working normally, you have already proved two things: the building is delivering hot primary water to your flat, and a good part of your HIU is working. That rules out a plant room failure, a closed riser valve and a dead unit all at once.
The fault is on the heating side specifically — which is a much shorter list of possibilities, and usually a cheaper fix.
Match Your Symptom to the Cause
All radiators cold, hot water fine
Likely cause: Heating zone valve or actuator failure inside the HIU, or no demand signal reaching the unit from the thermostat or programmer
Try first: Check the programmer is calling for heat and the thermostat is set above room temperature
Radiators cold at top, warm at bottom
Likely cause: Trapped air in the radiator
Try first: Bleed the radiators, starting furthest from the HIU
Radiators cold at bottom, warm at top
Likely cause: Sludge and magnetite settled in the bottom of the radiator
Try first: Needs a powerflush — not a DIY fix
One radiator cold, the rest fine
Likely cause: Stuck TRV pin, closed lockshield valve, or air in that radiator
Try first: Check both valves are open; a stuck TRV pin can sometimes be freed
Radiators lukewarm, never reach full heat
Likely cause: Partly open zone valve, low system pressure, or a scaled heat exchanger restricting the circuit
Try first: Check the pressure gauge if your unit has one
Heating works briefly then stops
Likely cause: Control cycling on a faulty temperature sensor, or an overheat thermostat tripping
Try first: Note how long it runs before cutting out — useful for the engineer
Check These Before You Call Anyone
A surprising number of “no heating” callouts turn out to be controls rather than a fault. Run through these first — they cost nothing and take five minutes.
- Is the programmer calling for heat? Check it is in a heating period and not on a summer or hot-water-only setting. Timers lose their schedule after a power cut.
- Is the room thermostat set above the current room temperature? If the room is 20°C and the stat is set to 19°C, nothing will fire. Turn it well up as a test.
- Does the thermostat need batteries? Wireless thermostats are a very common cause. A blank or faint display is the giveaway.
- Are the radiator valves open? Check both ends of each radiator — the TRV and the lockshield.
- Is there any system pressure? If your unit has a pressure gauge and it reads near zero, the heating circuit has lost water and needs attention.
- Are your neighbours affected? If several flats lost heating at the same time, it is a communal issue for your managing agent, not your HIU.
The Most Common Actual Fault
When the controls check out and every radiator is stone cold, the single most frequent cause we find is a failed heating zone valve actuator inside the HIU.
The actuator is a small motorised head that opens the valve letting primary heat into your radiator circuit. When it fails — the motor burns out, or the valve beneath it seizes — the heating circuit simply never opens. Hot water carries on working perfectly, because it runs through a different valve.
It is a routine repair. The part is inexpensive, it is one of the components we carry on the van, and it is normally done in a single visit.
The other recurring cause is sludge. Magnetite builds up in radiator circuits over years and settles in the bottom of radiators and in narrow sections of the HIU. The classic sign is radiators warm at the top and cold at the bottom, often with the circuit never quite reaching temperature. That needs a powerflush rather than a part swap.
When It Is Not Your HIU at All
Two situations point away from your unit entirely:
- Several flats affected simultaneously. This is a communal heating or plant room problem. Report it to your managing agent or housing provider rather than arranging your own engineer — the cost should sit with the building, not you.
- It started immediately after works in the building. If the system has been drained and refilled, air in the risers is common and the building's contractor should return to vent it properly.
Who Pays for the Repair?
In most London leasehold blocks, the communal system up to your flat is the freeholder's responsibility, while the HIU inside your flat may be yours — but leases vary considerably and some blocks include in-flat HIUs in the service charge. Check your lease, or ask your managing agent, before you commission anything.
If you rent, it is your landlord's responsibility. Under the Landlord and Tenant Act 1985, landlords must keep installations for space heating and hot water in repair and proper working order.